Integrating Fluorescent Ligands into Flow Cytometry: Enhancing GPCR Analysis Beyond Traditional Antibody Staining

Updated: Sep 10

Flow cytometry, a laser-based method, is used to examine single cells suspended in a fluid. By measuring the way these cells scatter light and emit fluorescence, they can be identified, quantified and isolated into distinct cell populations.



Antibody staining is a technique that helps differentiate cells and has been used in flow cytometry for a long time. In order to expand its role in GPCRs, which antibodies tend to have more trouble binding to. Fluorescent ligands based on small molecules bind to the functional sites of receptors in live cells, no need for cell fixation or permeabilization. This facilitates the study of receptor dynamics, ligand binding and signaling in real time.


Figure 1. Schematic representation of the flow cytometry technique. Adapted from Drescher H, Weiskirchen S, Weiskirchen R. Flow Cytometry: A Blessing and a Curse. Biomedicines. 2021 Nov 4;9(11):1613.
Figure 1. Schematic representation of the flow cytometry technique. Adapted from Drescher H, Weiskirchen S, Weiskirchen R. Flow Cytometry: A Blessing and a Curse. Biomedicines. 2021 Nov 4;9(11):1613.

 

Using Fluorescent Ligands Over Antibodies in Flow Cytometry Assays: Key Advantages


These are key limitations of antibody staining in flow cytometry:


1.       No need for fixation and permeabilization

This step can modify receptor conformation and affect downstream signaling.


2.       Antibody batch-to-batch differences

Antibodies from different lots may show different characteristics.


3.       Specificity issues

Some antibodies bind to shared epitopes across different proteins, which may lead to nonspecific staining.


These limitations can impact data quality, reproducibility, and assay flexibility. Fluorescent ligands provide some key advantages that may solve these issues:


1.       Direct binding to functional sites

They bind to the active site of the receptor, which also proves kinetic and binding affinity information, not just presence.


2.       Compatibility with live cells

No need for fixation of permeabilization. Ideal for live cell low cytometry, which means you can monitor while preserving cellular integrity.


3.       Higher specificity and reproducibility

Well characterized ligands show consistent and selective binding to their target, lowering background noise.



How Fluorescent Ligands Transform Flow Cytometry in GPCR Analysis


GPCRs are a tough target in traditional antibody staining due to their membrane localization, low expression and complex conformations. Using the advantages enumerated previously, fluorescent ligands provide new capabilities:


-            Real time tracking

they allow continuous observation of GPCR interactions and following internalization and recycling upon activation.


-            High-throughput applications

Bright and stable fluorescent ligands can be used in HTS, fast tracking the assessment of GPCR interactions and signaling pathways.


-            Biased signaling detection

Biased pharmacophores may be used in conjunction with fluorescent tags to study biased signaling pathways, improving our understanding of GPCR functional diversity and their therapeutic potential.


These capabilities help with the quantification of functional receptor expression, following internalization, analyzing ligand-receptor interactions, which are not as detectable with antibodies.

Innovations in the fluorophore tags, such as pH sensitive probes, can further improve signal-to-noise ratio and reduce background interference.



Optimizing Fluorescence Channels and Fluorophore Selection for GPCR-Targeted Flow Cytometry


The fluorophore tag is a key part of the flow cytometry assay, as there are several key factors to be considered:


1.       Tag brightness and stability: the brighter and more stable the better the assay outcome.


2.       Emission spectra and overlap: cell autofluorescence is usually found in the green region of the emission spectra, so using distinct fluorophores closer to red simplifies the process.



3.       Autofluorescence and multiplexing: Using far-red or near-infrared fluorophores can reduce background and support multi-parametric assays.


4.       Instrument compatibility: Fluorophores should match the laser and detector configurations of the cytometer.



The optimization of fluorescence channels is also important. The compatibility of fluorophore and detector is key to ensure a clean signal.

Innovations such as spectral flow cytometry and fluorescence lifetime imaging also expand the capabilities of these tags. Fluorescent ligands are an advancement for flow cytometry applications in the GPCR field, as they overcome many limitations of the antibody-based methods.



At Celtarys, we support this transition by offering optimized fluorescent ligands specifically designed for GPCR targets, including CELT-240 for hD2/D3 dopamine receptors and CELT-483 for the hσ1/σ2 sigma receptor. In addition, we provide detailed protocols and expert guidance to help you achieve reliable, actionable flow cytometry results. 


Figure 2. CELT-240 in flow cytometry binding assays is suitable to measure the affinity of compounds for the D2/D3 receptors. Flow Cytometry validation performed in the Oncological Pharmacology Laboratory of the University of Turin. 
Figure 2. CELT-240 in flow cytometry binding assays is suitable to measure the affinity of compounds for the D2/D3 receptors. Flow Cytometry validation performed in the Oncological Pharmacology Laboratory of the University of Turin. 

 


References Drescher H, Weiskirchen S, Weiskirchen R. Flow Cytometry: A Blessing and a Curse. Biomedicines. 2021 Nov 4;9(11):1613. doi: 10.3390/biomedicines9111613

University of Virginia Flow Cytometry Facility. Critical Aspects of Staining Cells [Internet]. Charlottesville (VA): University of Virginia; [cited 2025 May 16]. Available from: https://med.virginia.edu/flow-cytometry-facility/wp-content/uploads/sites/170/2015/10/Critical-Aspects-of-Staining-Cells.pdf

Böhme I, Beck-Sickinger AG. Illuminating the life of GPCRs. Cell Commun Signal. 2009 Jul 14;7:16. doi: 10.1186/1478-811X-7-16 

Siddiqui S, Livák F. Principles of Advanced Flow Cytometry: A Practical Guide. Methods Mol Biol. 2023;2580:89-114. doi: 10.1007/978-1-0716-2740-2_5

Comments

Rated 0 out of 5 stars.
No ratings yet

Add a rating
bottom of page